IOM 1200AFBG.1
REV. A 12541
IOM 1200AFBG.1
MAY 2006
Installation, Operation and Maintenance Manual for
Weight Loaded Fiberglass Valves
Models 1200A, 1220A, 1260A, 1300A, 1360A, 2300A, 1720A, 1760A
Zobrazit stránku 0
1 2 3 4 5 6 ... 16 17

Shrnutí obsahu

Strany 1

IOM 1200AFBG.1 REV. A 12541 IOM 1200AFBG.1 MAY 2006 Installation, Operation and Maintenance Manual for Weight Loaded Fiberglass Valves Mo

Strany 2 - INTRODUCTION:

9Groth Model 1220A Pressure/Vacuum Relief Valve Fig. 9 Epoxy Vinyl Ester Resin ITEM NAME 411-45 411-45 - PVDF 470-36 Furan 1 Body

Strany 3 - VALVE DESIGN AND FUNCTION:

10Groth Model 1260A/1760A Pressure/Vacuum Relief Valve Fig. 10 Epoxy Vinyl Ester Resin ITEM NAME 411-45 411-45 w/ PVDF

Strany 4 - INSPECTION AND STORAGE:

11Groth Model 1300A Pressure/Vacuum Relief Valve Fig. 11 Epoxy Vinyl Ester Resin ITEM NAME 411-45 411-45 w/ PVDF

Strany 5 - Notes:

12Groth Model 1360A Pressure/Vacuum Relief Valve Fig. 12 Epoxy Vinyl Ester Resin ITEM NAME 411-45 411-45 470-36 Furan

Strany 6

13Groth Model 2300A Pressure/Vacuum Relief Valve Fig. 13 Epoxy Vinyl Ester Resin ITEM NAME 411-45 411-45 w/ Kynar 470-36 Furan

Strany 7 - Quantity

14Table 6: LIST OF ABBREVIATIONS ANSI American National Standard Lb.-Ft. Pound Foot PRESS Pressure API American Petroleum Institute MA

Strany 8 - TEST PROCEDURE:

15 The nameplate on the Valve contains the Model Number, Serial Number, set pressures and flow capacity at a specified over-pressure. The Model Numb

Strany 9

16 TABLE 5 - Maximum Vacuum Settings with Resin Encapsulated Lead Weights Valve Size OSI IN WC mbar 2” 28 48.4 121 3” 32 55.4 138 4” 32 55.4 138

Strany 10

© Copyright Groth Corporation 1999 1TABLE OF CONTENTS: DESCRIPTION PAGE Introduction 1 Valve Design & Function 2 Safety Warnings 3 Inspection a

Strany 11 - Fig. 10

2VALVE DESIGN AND FUNCTION: Fig. 1 - Typical Tank Installation Tank protection equipment typically includes an operating valve

Strany 12 - Fig. 11

3SAFETY WARNINGS: This section is an overview of safety guidelines that should be followed during the installation, operation and maintenance of Grot

Strany 13

4The following guidelines should be observed at installation: 1. Inspect the gasket seating surface of the tank nozzle flange. It must be clean, fr

Strany 14 - Weatherhood Post

5MAINTENANCE: Groth Corporation recommends that all service performed on a pressure/vacuum relief valve be done at the factory or a factory authorize

Strany 15

6TABLE 3: Part Numbers - Spare Parts * Valve Size Component Stem 2" 3" 4" 6" 8" 10" 12" Dphgm, 10 m

Strany 16 - PRODUCT LIMITED WARRANTY

7TEST PROCEDURE: 1. A chart showing nominal pallet assembly weights for three common units of pressure is shown below in Table 4. Before starting to

Strany 17

8Groth Model 1200A Pressure/Vacuum Relief Valve Fig. 8 Epoxy Vinyl Ester Resin ITEM DESCRIPTION 411-45 411-45 – PVDF 470-

Příbuzné modely 1220A | 1260A | 1300A | 1360A | 2300A | 1720A | 1760A |

Komentáře k této Příručce